© Inspire Medical Systems, Inc. All Rights Reserved © 2025 Inspire Medical Systems, Inc. All Rights Reserved Inspire Product Theater Inspire V Real-World Experience One Less Step. Same Proven Results Presents


 
Inspire Product Theater – Faculty Ryan Soose, MD University of Pittsburgh School of Medicine Pittsburgh, PA Tom Kaffenberger, MD University of Pittsburgh School of Medicine Pittsburgh, PA C-00156.1 Maria Suurna, MD University of Miami Miami, FL Colorado ENT & Allergy Colorado Springs, CO Mass Eye & Ear Boston, MA Nic Beckmann, DO Phil Huyett, MD


 
Inspire Product Theater Agenda C-00156.1 • Early-User Implant Experience • Preliminary Patient Outcomes Data • Q&A Discussion with Expert Panel


 
Next Generation Hypoglossal Nerve Stimulation for the Treatment of Obstructive Sleep Apnea Results of the Inspire V Study Singapore General Hospital National University Hospital


 
Inspire Therapy • A treatment for OSA patients who are unable to use CPAP In a 60-90 minute outpatient procedure Using the Inspire Remote Using the SleepSyncTM patient management platform 5 Surgically Placed Patient Controlled Managed by SleepSyncTM


 
Inspire V System 6 The Fifth Generation of a proven therapy for OSA is designed for a(n): • Simplified procedure • Enhanced patient comfort • More efficient patient management


 
7 Simplified Procedure One Less Step With a new integrated respiratory sensor, Inspire V eliminates the need to place a separate sensing lead, simplifying the procedure. 2 components 2 incisions 3 components 2 incisions3 components 3 incisions Inspire V Inspire IV 2- incision approach Initial Inspire IV


 
Precision Stimulation Timing Stimulation delivered when the airway is most vulnerable to collapse during the inspiratory phase inspiration inspiration airflow stimulation Accelerometer detects breathing


 
9 Tailored Therapy Options Designed for Patient Comfort Program patient therapy levels at half or quarter step sizes with Inspire V when needed Stimulation Step Sizes Gently initiate therapy, without disturbing sleep with Inspire V when needed Ramp Option 5, 10, 15 minute options


 
Inspire V Study Design • Prospective, multicenter cohort study • Designed to confirm effectiveness of Inspire V System • Two investigational centers (Singapore) • Singapore General Hospital (Prof. Toh Song Tar; Dr. Shaun Loh; Dr. Adele Ng) • National University Hospital (Dr. Crystal Cheong) • 44 Subjects • Patient Population • Subjects 21 years or age or older with moderate to severe OSA who meet the Inspire V UAS system indications for use and are willing to participate in the clinical trial


 
Study Objectives Primary Endpoint: Non-inferiority of Inspire V vs Inspire IV technology as measured by IPOP (Inspiratory Phase Overlap Percent) during in-lab polysomnography. Secondary Endpoints: • Change in Apnea – Hypopnea Index (AHI) at 6 Months post-activation • Mean Epworth Sleepiness Scale (ESS) is less than 10 at 6 Months post- activation Ancillary Information: • Therapy Adherence (hours/day) at 6 months post-activation • Procedure and Device/therapy Adverse Events • IPOP at 6 months post-activation • Mean Function Outcomes of Sleep Questionnaire (FOSQ) at 6 months post- activation


 
Clinical Study Design Baseline <90 days pre- implant Implant Day 0 Activation Clinic Visit 30 ± 14 days post-implant Activation Sleep Study ~2-3 months post activation 3 Month FU 90 ± 30 days post-activation 6 Month FU 180 ± 30 days post-activation PSG (no titration) for IPOP Analysis (1º endpoint) PSG (Titration) PSG (no titration) 2º endpoint


 
Study Results to Date Variable Subjects (n=44) Male 39 (88.6%) Age (years)* 55.7 ± 10.2 (35-73) Race Chinese 39 (88.6%) Indian 4 (9.1%) Malay 1 (2.3%) BMI (kg/m2)* 26.9 ± 2.8 (20.4 – 31.6) AHI (events/hr)* 37.0 ± 15.2 (15.2 – 65.0) ESS* 10.9 ± 5.9 (0-23) • Prior OSA treatment (other than surgery): 86.4% • Prior airway surgeries: 40.9% • Cardiovascular comorbidity: 63.6% • Hypertension: 59.1% • Other Sleep comorbidities: 11.4% Demographics Medical History Study Status Enrollments N=54 Screen Failures N=10 Implanted Patients N=44 Primary Endpoint N=44 6 Month Study End N=39* Early Exit: 1 Final Visit Scheduled: 4 *Mean±SD (range) *37 6M PSGs available (6 sleep studies pending)


 
Study Results to Date Procedure Details • 100% successful Implants (n=44) • 20.4% reduction in implant time (vs Inspire IV) • No serious intraoperative adverse events


 
Primary Endpoint Inspiratory Phase Overlap Percent (IPOP)* Sensing performance is measured using IPOP during in-lab PSG IPOP measures how well inspiration is covered by stimulation. *Based on the mean inspiratory overlap derived from Inspire IV analysis and a non-inferiority margin of 4.59, the following hypothesis will be tested: H0: 𝑥𝑥 ̅_𝐼𝐼𝑂𝑂<74.8%, Ha: 𝑥𝑥 ̅_𝐼𝐼𝑂𝑂≥74.8%, where 𝑥𝑥 ̅_𝐼𝐼𝑂𝑂 is the mean inspiratory overlap of Inspire V. (example) 100% IPOP100% IPOP 100% IPOP


 
Inspire V Sensing Performance Primary Endpoint: Inspiratory Phase Overlap Percent (IPOP) Results** Inspire V IPOP 87.1% Confidence Interval: 85.5%-88.8% Inspire IV* IPOP 79.4% Non-inferiority Margin: 4.6% Sensing with Inspire V is SUPERIOR to Inspire IV *Inclusive of previous Inspire generations (data collected during the Wear Study) **Inspire V was found to be non-inferior to Inspire IV (retrospective control from Wear Study); superiority was subsequently tested No device setting changes were made during the Inspire V IPOP measurement PSGs


 
Therapy Adherence and Device Parameters Comfort Settings Utilization % patient use* N=44 Small Step Size 54.5% Start Impulse 31.8% Ramp 22.7% Objective Therapy Adherence 5.5 ± 1.7 hours / night (n=44 at a mean of 246 days post-implant) *at most recently reported visit


 
Interim* 6 Month Results: Effectiveness *Total of n=43 patients projected at study completion (6 sleep studies pending); early exit: n=1 **6M PSGs were conducted at 1 therapeutic amplitude throughout the entire night; no changes were made to device settings 34.4 8.3 0 5 10 15 20 25 30 35 40 Baseline (n=44) 6 Month (n=37) M ed ia n AH I ( ev en ts /h r) Apnea-Hypopnea Index 11 7 0 2 4 6 8 10 12 Baseline (n=44) 6 Month (n=41) M ed ia n ES S Epworth Sleepiness Scale All-night PSGs**


 
Interim 6 Month Results: Safety • No revisions/explants • Serious Adverse Events • Wound dehiscence (resolved): 2 • Patients provided antibiotics and event resolved within two weeks post-op • Non-serious Adverse Events • Neuropraxia (resolved): 1 • Right marginal mandibular weakness (resolved): 1 • Difficulty speaking (resolved): 1 • Hypotension during implant (resolved): 1 • Hypertrophic scar: 3


 
• Simplified implant procedure • 20.4% reduction in implant time • Elimination of respiratory sense lead • Accelerometer technology • Inspire V sensing is superior to previous Inspire generations • Strong objective therapy adherence at 5.5 hrs/night • Clinically significant reductions in OSA severity • Clinically significant improvements in key quality of life measures Inspire V Clinical Study Conclusions


 
© 2024 Inspire Medical Systems, Inc. All Rights Reserved Inspire V Limited Market Release Data as of October 3, 2025


 
© Inspire Medical Systems, Inc. All Rights Reserved Inspire V Limited Market Release with 101 patients at 11 U.S. Centers Tracking data to date with 34 patients with AHI data 60 day check in 101/101 Activation 101/101 30 day check in 101/101 IMPLANT 101/101 Sleep Study 34/101 Avg Strat Amp 1.1v Patients to date Avg. Amp. 1.7v Avg Adherence 6.7 Hours 85% nights used Patients utilizing new features Small Step Size – 20%​ Start Impulse – 17%​ Ramp – 20% Avg Amp. 1.4v Avg Adherence 7.2 hours Avg Amp. 1.7v Avg Adherence 6.8 hours • 100% Successful implants • No serious adverse events • 5 non-serious adverse events • Neuropraxia – resolved before activation(2) • Mild marginal mandibular weakness(1) • Mild ear pain(1) • Incision swelling/tenderness(1)


 
Thank You. © 2024 Inspire Medical Systems, Inc. All Rights Reserved


 
Inspire V Experience at MEE Phil Huyett, MD Director of Sleep Surgery Massachusetts Eye and Ear Assistant Professor Harvard Medical School


 
Disclosures • Inspire medical systems – Research support – Educational consultant • Nyxoah – Research support • Part of limited release in February • Still having discussions with insurance!


 
Inspire V • Faster/less general anesthesia time • No more respiratory sensor revisions • ?reduced PTX % • ?faster recovery • ?less post op pain


 
HGNS Model Case Gender Age (years) BMI (kg/m2) Surgical time (min) 1st incision to cuff placement (min) V LA MEE647 F 52 27.5 41 15 V LA MEE650 M 51 21.9 38 14 V LA MEE660 M 55 31.3 37 11 V LA mean 52.7 26.9 38.7 13.3 V MEE646 M 59 26.5 38 15 V MEE672 M 54 30.9 36 16 V MEE670 M 53 22.9 41 17 V MEE653 M 59 32.8 28 10 V MEE656 M 46 28.6 30 10 V MEE658 M 57 31.8 34 12 V mean 54.7 28.9 34.5 13.3 IV MEE648 M 59 21.8 45 18 IV MEE651 M 68 33.5 48 27 IV MEE643 M 61 32.5 67 24 IV MEE644 M 76 29.1 40 17 IV MEE645 F 73 32.1 40 14 IV MEE649 M 71 26.2 41 19 IV MEE673 M 40 28 42 20 IV MEE674 M 38 26.5 43 25 IV MEE652 M 52 30.6 48 22 IV MEE671 F 78 21.8 41 15 IV MEE654 M 37 24.2 45 27 IV mean 59.4 27.8 45.5 20.7 = 24.2% less time Standard IV Standard V


 
HGNS Model Case Gender Age (years) BMI (kg/m2) Surgical time (min) 1st incision to cuff placement (min) V LA MEE647 F 52 27.5 41 15 V LA MEE650 M 51 21.9 38 14 V LA MEE660 M 55 31.3 37 11 V LA mean 52.7 26.9 38.7 13.3 V MEE646 M 59 26.5 38 15 V MEE672 M 54 30.9 36 16 V MEE670 M 53 22.9 41 17 V MEE653 M 59 32.8 28 10 V MEE656 M 46 28.6 30 10 V MEE658 M 57 31.8 34 12 V mean 54.7 28.9 34.5 13.3 IV MEE648 M 59 21.8 45 18 IV MEE651 M 68 33.5 48 27 IV MEE643 M 61 32.5 67 24 IV MEE644 M 76 29.1 40 17 IV MEE645 F 73 32.1 40 14 IV MEE649 M 71 26.2 41 19 IV MEE673 M 40 28 42 20 IV MEE674 M 38 26.5 43 25 IV MEE652 M 52 30.6 48 22 IV MEE671 F 78 21.8 41 15 IV MEE654 M 37 24.2 45 27 IV mean 59.4 27.8 45.5 20.7 = 15% less time than IV Standard IV LA V


 
Inspire V LA surgical pearls • IPG replacement probably more challenging • Doesn’t add significant time • Be sure to parachute IPG medially • Alternative to other HGNS systems for patients who don’t want anterior chest incision


 
Initial Outcomes Inspire V Nic Beckmann, DO Colorado ENT and Allergy Colorado Springs, CO


 
Inspire V SYSTEM The Fifth Generation of a proven therapy for OSA is designed for a: • Simplified procedure • Enhanced patient comfort • More efficient patient management


 
• From a 3 component/incision procedure -> 2 component procedure Consistent Innovation Leads to Simplified Procedure 2 components 2 incisions 3 components 2 incisions 3 components 3 incisions One Less Step with Inspire V


 
Deliver Stimulation At The Right Time With A Synchronized Stimulation Algorithm* * Accelerometer Control Performs Comparable to Pressure Sensor Control of Hypoglossal Nerve Stimulation Timing Asim Roy, MD1, Karl Doghramji, MD2, Shalini Manchanda, MD3, Israel Byrd, PhD4, James Manne-Nicholas4, Christopher K Thorp, MS4, Dave Dieken4, Jason Cornelius, MD5, SLEEP2024 Accelerometer


 
34 Tailored Therapy Options Designed for Patient Comfort Program patient therapy levels at half or quarter step sizes with Inspire V when needed Stimulation Step Sizes Gently initiate therapy, without disturbing sleep with Inspire V when needed Ramp Option 5, 10, 15 minute options


 
CO Reimbursement Note: In July 2025, the Center for Medicare Services (CMS) proposed the Hospital and Physician Medicare payment starting January 1, 2026 will change (pending final approval in November 2025): • Implant (hospital) Medicare reimbursement will increase from $30,473.59 to $31,751.65 • Inspire IV physician payment (64582) will decrease from $815.78 to $723.56 • Inspire V physician payment (64568) will increase from $593.56 to $660.33


 
• Flip rooms with surgical assist – Multiple stacked cases on OR days • Prior to V averaging 9 cases • Post V averaging 12 cases – 8 inspires with parotid and tonsils – 3 tonsils/adenoids, tubes, 3 septo/turbs combined with 6 implants – Intraoperative time saving allows for better utilization of block time Increasing Capacity


 
Patient Volume


 
Year over Year Patients Treated


 
• Questions Thank you!


 
Disclaimer

The opinions and information contained herein have been obtained or derived from sources believed to be reliable, but Boardroom Alpha cannot guarantee its accuracy and completeness, and that of the opinions based thereon.

This report contains opinions and is provided for informational purposes only – it does not constitute investment, legal or tax advice. You should not rely solely upon the research herein for purposes of transacting securities or other investments, and you are encouraged to conduct your own research and due diligence, and to seek the advice of a qualified securities professional before you make any investment.

None of the information contained in this report constitutes, or is intended to constitute a recommendation by Boardroom Alpha of any particular security or trading strategy or a determination by Boardroom Alpha that any security or trading strategy is suitable for any specific person. To the extent any of the information contained herein may be deemed to be investment advice, such information is impersonal and not tailored to the investment needs of any specific person.

No representation or warranty, expressed or implied, is made on behalf of Boardroom Alpha as to the accuracy or completeness of the information contained herein. Boardroom Alpha does not accept any liability for any direct, indirect or consequential loss or damage suffered by any person as a result of relying on all or any part of this research and any liability is expressly disclaimed.

Full disclaimer